In this guide we will be looking at how we can use different storage policy on vSAN datastore to fine tune performance for the virtual machines running on a vSAN Datastore . We will look at different tools which can be run from the guest level and also few tests run with HCIBench .

Before you start reading thru this blog I highly encourage you to check out “[Achieve-Best-Performance-on-vSAN](https://admin.hareeshkg.bid/achieve-best-performance-on-vsan)” to get any understanding vSAN performance benchmark tool called HCIBench.

Please ensure to also go thru the post “[understanding-vm-storage-policies](https://admin.hareeshkg.bid/post/understanding-vm-storage-policies/)” to get a hold of storage policy base management and different rule-sets / parameters within storage policy .

In this test case , I got my hands on one of a three Node Dell-Servers running vSAN 6.7 U1 All-FLASH with Dedupe and compression enabled , each host has 1 disk group with 1 SSD cache tier drive and two capacity tier drive and I ran two different BenchMarking tool “HCIBench” from VMware on this cluster and another in-guest level Disk Benchmark tool called “Crystal DiskMark” against individual VMDKs to compare performance with two different storage policy .

### Hardware Specs

**\- server model and BIOS version** Dell Inc. PowerEdge R630 | BIOS: 2.7.1

```
    #[Rackmount] [id:35865] DELL PowerEdge R630
    #vcgLink = 'https://www.vmware.com/resources/compatibility/detail.php?deviceCategory=server&productid=35865'
    #picture = 'https://www.google.com/search?q=DELL%20PowerEdge%20R630&source=lnms&tbm=isch&sa=X'

```

**\- CPU type** Intel(R) Xeon(R) CPU E5-2630 v3 @ 2.40GHz # Link: '[http://www.google.com/#q=E5-2630+ark.intel.com](http://www.google.com/?ref=admin.hareeshkg.bid#q=E5-2630+ark.intel.com)' Number of packages (pCPU):2 Number of cores (total):16 Hyperthreading state: 3 -> enabled

**\- CPU microcode revision** Current Revision:0x0000003d

**\- Network Interface Card** 2X - Intel Corporation Ethernet Controller 10 Gigabit X540-AT2

**\- Host Bus Adapter** vmhba driver driver version model

---

vmhba0 lsi\_mr3 7.703.18.00-1OEM.650.0.0.4598673 Avago (LSI) PERC H730 Mini

**\- HBA queue settings** PERC H730 Mini Integrated : 891

**Controller HCL :** [https://www.vmware.com/resources/compatibility/detail.php?deviceCategory=vsanio&productid=34859](https://www.vmware.com/resources/compatibility/detail.php?deviceCategory=vsanio&productid=34859&ref=admin.hareeshkg.bid)

- **Drives used for vSAN** **esxcli storage core device list |grep -i 'Devfs Path|vendor|Model|Revision|Raid|size' | egrep -v Queue |sed 'N;N;N;N;N;s/\\n//g'**Size: 190782 Devfs Path: /vmfs/devices/disks/naa.55cd2e414d9b2945 **Model: INTEL SSDSC2BA20** Revision: DL2B RAID Level: NA Size: 915715 Devfs Path: /vmfs/devices/disks/naa.5002538c4044d6ab **Model: MZ7KM960HAHP00D3** Revision: GB52 RAID Level: NA Size: 915715 Devfs Path: /vmfs/devices/disks/naa.5002538c4044d6**a**d **Model: MZ7KM960HAHP00D3** Revision: GB52 RAID Level: NA

**Cache Tier HCL :** [https://www.vmware.com/resources/compatibility/detail.php?deviceCategory=ssd&productid=39831](https://www.vmware.com/resources/compatibility/detail.php?deviceCategory=ssd&productid=39831&ref=admin.hareeshkg.bid) \- **"CLASS-E 30,000-100,000 writes per second"** **Capacity Tier HCL :** [https://www.vmware.com/resources/compatibility/detail.php?deviceCategory=ssd&productid=39915](https://www.vmware.com/resources/compatibility/detail.php?deviceCategory=ssd&productid=39915&ref=admin.hareeshkg.bid) \- **"CLASS D: 20,000-30,000 writes per second"**

### RUN-\*\*HCIBench \*\*

From the above specs its clear that we can only define the storage policy with fault tolerance method as RAID-1 with stripe width either as SW=1 or SW=2 going higher stripe width is point less as we only have two capacity tier drives and one Disk group . Hence I did run different tests with SW=1 and SW=2 . Here are the result comparison .

***Note: The following illustrations is used only to show difference between two storage policy , do not use them as expected benchmark results in your environment as these results are purely environment dependent .***

1. Test result on **Storage Policy Definition as failures to tolerate -1 and stripe-width=1** gives with the workload definition “***6 VMs,*** ***8-vDisks, 80% working set , 4K Block Size, 70% read% and 80% random packets , number of threads as 4***” is **31111 IOPS** and **throughput of 121MB/s** .
2. The same workload was next run with **Storage Policy Definition as failures to tolerate -1 and stripe-width=2** , we see that this policy was able deliver **59017 IOPS and throughput of 230MB/s** this is almost two times the IOPS and throughput achieved previously by only increasing the stripe width from one to two .

Please click thru the following Images to see test results :

![](https://admin.hareeshkg.bid/content/images/2026/09/how-storage-policy-affects-performance-on-vsan-Table_1-1024x50.png)

![](https://admin.hareeshkg.bid/content/images/2026/09/how-storage-policy-affects-performance-on-vsan-FTT-1-SW-1-vSANCLIENT-1024x361.png)

![](https://admin.hareeshkg.bid/content/images/2026/09/how-storage-policy-affects-performance-on-vsan-FTT-1-SW-2-vSANCLIENT-1024x382.png)

### **Running Guest Level BenchMark!**

To validate if we are actually benefited from higher stripe width , we may also run some guest level performance benchmark tests . For this test I chose to use/run [Crystal-DiskMark Utility](https://osdn.net/projects/crystaldiskmark/downloads/68624/CrystalDiskMark6%5F0%5F2.zip/?ref=admin.hareeshkg.bid) , there are many tools available in the market depending on the type of Guest-OS .

![](https://admin.hareeshkg.bid/content/images/2026/09/how-storage-policy-affects-performance-on-vsan-Download_crystal_diskmark-1024x664.png)

I picked up one of a windows server-2k16 VM , presented two new hard-disks of size 2GB each , applied the vSAN-Default-Storage-Policy on the first vmdk which is nothing but FTT=1 ,SW=1 and FTT=1 ,SW=2 storage policy is applied on the second disk. Next I ran similar workload test on both these drives , it is clearly evident that the writes are always benefited when the components are striped across multiple capacity tier SSD drives .

![](https://admin.hareeshkg.bid/content/images/2026/09/how-storage-policy-affects-performance-on-vsan-Guest-setup_0.png)

![](https://admin.hareeshkg.bid/content/images/2026/09/how-storage-policy-affects-performance-on-vsan-Guest-setup_1.png)

![](https://admin.hareeshkg.bid/content/images/2026/09/how-storage-policy-affects-performance-on-vsan-Guest-setup_2.png)

#### Running Crystal Diskmark against two drives!

![](https://admin.hareeshkg.bid/content/images/2026/09/how-storage-policy-affects-performance-on-vsan-crystal_diskmark-exe-1.png)

\- Download and extract “CrystalDiskMark6\_0\_2.zip” , run the 64bit file

![](https://admin.hareeshkg.bid/content/images/2026/09/how-storage-policy-affects-performance-on-vsan-Result_run_ftt-1SW1-1024x579.png)

\- Configure Test Settings (queue and threads)and run the benchmark tool against the first drive with\*\* SPBM FTT=1 and SW=1 \*\*

![](https://admin.hareeshkg.bid/content/images/2026/09/how-storage-policy-affects-performance-on-vsan-Result_run_ftt-1SW2_final.png)

\- Run the same benchmark test against the second drive which use \*\*SPBM FTT=1 and SW=2 \*\*

From the above tests we see that the **J:Drive** which is with higher stripe width defined on the storage policy yields higher throughput especially in terms of writes which might be critical for most of the applications which are I/O intensive , also read is benefited since the reads are also served by two different capacity tier drive directly to the VMs (Only in All-Flash).

It is always recommended to run HCIBench and Guest level bench mark tests with different tool which can generate a very close/similar workload to that of real life application and find the sweet-spot (right storage policy) which yields best performance for the specific use case.

NOTE: A storage policy which is best suited for Application-A will not be the best storage policy for Application-B , its always recommended to run different tests of each application to find the correct storage policy . At times there will be contention at the virtual disk level because of the type of virtual storage controller like LSI-LOGIC , you might want to use PV-SCSI controller to get higher queue depth upto 256 for heavy VMS , see KB : [https://kb.vmware.com/s/article/2053145](https://kb.vmware.com/s/article/2053145?ref=admin.hareeshkg.bid) .

If you enjoyed this post, I’d be very grateful if you’d help it spread by emailing it to a friend, or sharing it on Twitter or Facebook. Thank you!